Home  
Map  


OS-7121        Optical Protection Switch           
For Automatic network path protection.  

  Block diagram of the OS-7121 Network Protection Switch


The OS-7121 is an optical path protection switch, providing a self healing network.  This optic switch detects loss of optical power in the primary optical path and automatically switches to the secondary (backup) path.  When the primary link is restored, the network path is restored to the primary path.   The optical protection switch can be controlled via three methods; front panel manual switch, remote control signal, or the automatic internal monitoring circuitry.  The switch also contains a transmitter splitter for creating the redundant transmit path.

The optical path through the units is purely optical; i.e. there is no optical to electrical to optical conversion.  So there is no electrical loss or electrical bandwidth limit on the fiber optic path.

Applications include telecom, datacom, ATM, and CATV systems. Click to view typical application.

Specifications Important Features
Switching Time  < 10 ms    · Switching time <10ms
Back Reflection  < -55 dB  · Fail-safe return to primary
Insertion Loss  < 1.5 dB       with loss of power
Cross Talk  < -50 dB · Single model for stand
Switch life cycle  > 1 million cycles       with or rack mount
Switch Sensitivity   -28 dBm  · Multimode & Single mode
Sensitivity Data Rate  DC to 3 Gb/s        Versions available
Optical Path Bandwidth   Gb/s  = no limit  · Status & Power Indicators
Optical Wavelengths  850/1310, or 1310/1550nm  
Optical Connectors  ST/PC,  FC/PC, or SC
Power Requirements*  120-230 VAC/DC or
   -48VDC
Operating Temperature  0 to +70 degrees C
Physical Size  5.0” x 7.0" x 1.0"
127mm x 178mm x 25.4mm
   

Note all specifications are subject to change without notice
* -48VDC models available by request.